Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units / Testing Equipment
8.2.6 Maintain the temperature of the cooling water at 21 +- 2°C. Determine the temperature of the cooling water immediately after it leaves the test apparatus for each cooling plate. 8.2.7 If an electric chilling apparatus is used to control the cooling plate temperature, maintain the required temperature as noted in 8.2.6. Measure the temperature…
Determination of Vicat Softening Temperature (VST) – Automatic/Manual Test Machine
5 Apparatus5.1 Heating equipment, consisting of one of the following (5.1.1, 5.1.2 or 5.1.3) that will accept aminimum of two test frame assemblies and a cooling device (5.1.4).The heating equipment shall be provided with means of temperature control, enabling the temperatureto be raised at a uniform rate of (50 ± 5) K/h or (120 ±…
DIN EN ISO 24234 Dentistry –Mercury and Alloys for Dental Amalgam / Determination of Creep , Dimensional Change, Compressive Strength
6.6 Preparation of test specimens to determine compliance with the requirements for creep, dimensional change and compressive strength6.6.1 TemperaturePrepare specimens at (23 +- 2) ºC, unless specified otherwise.6.6.2 MixingMix a mass of the amalgam sufficient to make a test cylinder (8 +- 1) mm high after condensation into the die shown in Figure 1. If…
ASTM D 5397 – Standard Test Method for Evaluation of Stress Crack Resistance of Polyolefin Geomembranes Using Notched Constant Tensile Load Test ( NCTL )- Testing Equipment
6 Apparatus6.1 Blanking Die—A die suitable for cutting test specimens to the dimensions and tolerances shown in Fig. 1.NOTE 1—The length of the specimen can be changed to suit the design of the test apparatus. However, there should be a constant neck section with length at least 13 mm (0.5 in.) long. The width should…
DIN EN ISO 21809-2 Epoxy Coatings for Buried or Submerged Pipelines / Particle Size of Epoxy Powder / Testing Equipment
A.6 Particle size of the epoxy powderA.6.1 EquipmentThe equipment required shall consist of the following:A.6.1.1 Air-jet sieving unit, with vacuum cleaner attachment and 150 µm and 250 µm screens.A.6.1.2 Balance, accurate to 0,01 g.A.6.2 ProcedureA.6.2.1 Weigh the sieve and one screen to the nearest 0,01 g. Place approximately 20 g of epoxy powder onto the…
FAR Part 25 Appendix F – Part III Test Method To Determine Flame Penetration Resistance of Cargo Compartment Liners
(a) Criteria for Acceptance. (1) At least three specimens of cargo compartment sidewall or ceiling liner panels must be tested. (2) Each specimen tested must simulate the cargo compartment sidewall or ceiling liner panel, including any design features, such as joints, lamp assemblies, etc., the failure of which would affect the capability of the liner…
Making Heatseals for Determination of Heatsealability of Flexible Webs as Measured by Seal Strength – Testing Equipment
Apparatus5.1 Heat sealer:5.1.1 Sealing Jaws—Two-heated jaws with flat sealing surfaces. Two-heated jaws are required to conduct Practice A. Practice B may be used with one-heated jaw only when the application is to commercial sealers with like configuration.5.1.1.1 Jaw Temperature Control—Each jaw must have independent temperature control. The recommended minimum precision of control is 6 1°C.5.1.1.2…
Testing Equipment – ISO 4898 Rigid Cellular Plastics — Thermal Insulation Products for Buildings — Specifications PF , EPS , XPS , PUR
5 Physical-property requirements 5.1 Categories Physical-property requirements are organized into product categories to meet purchaser and supplier needs over a range of end-use applications. Category I Suitable for non-load-bearing applications such as wall and cavity insulation, vented roofs, cavity wall insulation and similar applications. Category II Suitable for limited load-bearing applications such as in built-up…
ISO 4675 Rubber- or Plastics-Coated Fabrics -Low-Temperature Bend Test / Testing Equipment
4 Apparatus4.1 Cold chamber, in which the test pieces are exposed to low temperature, sufficient in size to contain the bending fixture used for testing the test pieces and to permit the Operation of the fixture to bend the test piece without removal from the chamber. The cold chamber shall also have sufficient work space…