Important Tests in the Area of Therapy Systems
Impact Test According to ISO 21809-3
G.1 GeneralThe test consists of verifying the strength of the FJC by the impact of a punch of defined shape falling directly onto the coating from a fixed height and at a fixed temperature. The test shall be carried out on pipes or cut samples. This test shall not be carried out on pipes with…
ISO 148-1 Metallic Materials –Charpy Pendulum Impact Test / Testing Equipment
7 Test equipment7.1 GeneralThe equipment used for all measurements shall be traceable to national or International Standards. They shall be calibrated within suitable intervals.7.2 Installation and verificationThe testing machine shall be installed and verified in accordance with ISO 148-2.7.3 StrikerThe striker geometry shall be specified as being either the 2 mm striker or the 8…
Laboratory Testing Equipment for Paraffin Wax
Paraffinic waxes are used for many industrial and consumer applications. We manufacture test and analysis equipment for paraffin wax to determine a wide range of chemical and physical properties. Paraffin was analysis can include purity, contamination, trace components, melting point, oil content and more. Here lets see some of these tests in brief. A- Drop…
ISO 17455 – Determination of the Oxygen Permeability of the Barrier Pipe – Testing Equipment
5 Apparatus The test assembly shall include the following main elements: NOTE 1 The test temperature (40°C or 80°C) is specified in the relevant product- or system standard. NOTE 2 1 ppb = 1 g/m3. 5.1 Oven, capable of maintaining a constant temperature of (40 ± 0,5) °C and/or (80 ± 0,5) °C. 5.2 Test…
IEC 60745-1 Hand-held Motor-Operated Electric Tools –Safety – Flexing Test Apparatus
Cord guards shall have adequate mechanical strength and shall retain these properties throughout extended normal use. Compliance is checked by the following test:The part of the tool comprising the cable entry, fitted with the cord guard and the flexible cable or cord for which the tool is designed, is fixed in the oscillating member of…
ASTM D 2239 – Standard Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter/ Testing Equipment
6. Requirements 6.1 Workmanship—The pipe shall be homogeneous throughout and free of visible cracks, holes, foreign inclusions, or other defects. The pipe shall be as uniform as commercially practicable in color, opacity, density, and other physical properties. See 5.1.2. 6.2 Dimensions and Tolerances: 6.2.1 Inside Diameters—The inside diameters and tolerances shall be as shown in…
ISO 18488 – Polyethylene (PE) Materials for Piping Systems — Determination of Strain Hardening Modulus in Relation to Slow Crack Growth — Testing Equipment
5 Apparatus5.1 Tensile-testing machine, complying with ISO 527-1 and capable of maintaining a test speed of (20 ± 2) mm/min.5.1.1 Load cell, which shall comply with Class 1, as defined in ISO 7500-1. The load cell shall be able to accurately measure forces in the range of 40 N for 0,30 mm thick samples and…
ISO 8796 – Polyethylene (PE) 25 Pipes for Irrigation Laterals — Susceptibility to Environmental Stress-Cracking Induced by Insert-type Fittings — Test Method and Specification – Testing Equipment
4.2 Apparatus Forced-air-circulation oven, maintained at 70 °C ± 2 °C, capable of re-establishing that temperature within five minutes after insertion of test pieces. NOTE — A constant-temperature bath may be used instead of the oven, provided it has the same thermal capabilities as specified for the oven. 4.3 Test pieces Five sections of the…